Level / Water Level / Product Density Measurement |
Measuring range |
Up to 4000 mm. |
Accuracy |
<0> |
Product density range |
690 to 800, 800 to 900 Kg/m3. |
Density measurement accuracy |
<= +/- 2.5 Kg/m3 |
Response time |
<= 1 Sec. |
Cable entry |
IP68 certified, sealed 4 core cable with 4 pin connector is provided for power and communication. |
Cable length |
Standard 1 m, Additional on request. |
Temperature Measurement |
Measuring Range |
-10°C to 80°C |
Accuracy |
+/- 0.5°C |
Resolution |
+/- 0.1°C |
Environmental Conditions |
Operating Pressure |
Atmospheric |
Operating temperature |
0°C to 55°C |
Process Fluid temperature |
-10°C to 60°C |
Hazardous Area Certification |
Explosion Proof |
Intrinsically safe Ex ia Ga IIB T6 IP68 as per IS/IEC 60079- |
0:2011. IS/IEC 60079-11:2006 & IS/IEC 60079=26:2006 |
suitable for Installation in “Zone 0” for gas groups Gr.IIB. |
Weather Proof |
IP 68 weatherproof enclosure as per IS/IEC 60529:2001. |