Level & Interface level measurement |
Measuring Range |
0-27000 mm (standard) |
0-37000 mm (on request) |
Level Accuracy |
+/- 0.6 mm* |
Sensitivity |
+/- 0.1 mm* |
Repeatability |
+/- 0.1 mm* |
Interface Accuracy |
+/- 2 mm* |
Resolution |
1 mm or 0.1 mm (selectable) |
Displacer Speed |
2400 mm / minute (maximum) |
Displacer diameter |
90 mm (standard) |
45 mm and 65 mm (optional) |
Density measurement accuracy |
|
On demand |
+/- 0.005 gm/cc |
Real time |
+/- 0.08 % |
With a pressure transmitter of accuracy ± 0.04% of |
URL. Accuracy of real time density measurement is a |
function of the accuracy of pressure transmitter. |
Temperature Measurement |
Using external temperature sensor |
Measuring Range |
-200°C to +200°C |
Accuracy |
+ /- 0.2°C |
Resolution |
0.1°C |
Sensor type |
RTD spot / Multi Point averaging (Max. 14 points) |
LPG mass measurement |
|
Accuracy |
+/- 1.3% of reading with SG density |
+/- 0.3% of reading with manually entered density |
Resolution |
0.01 MT |
Protection |
Flameproof to IS/IEC 60079-1:2007, Zone 1, Gr. IIA & IIB |
Weatherproof IP65 as per IS/IEC |
Terminals for temperature sensor |
Intrinsically safe to IS/IEC 60079-11:xxxx, Ex ia IIA and IIB T6 |
Operating Temperature |
-10°C to +60°C |
Power Supply |
110/230 Vac, +/- 10%, 50 Hz, 1 phase, mains isolated, 25 VA |
SIL2 outputs |
4-20 mA output proportional to level and/or |
2 nos. Alarm Relay Contacts. |